KH-D series deutz generator, power coverage from 22KW to 120KW, adopt DEUTZ 226B series low power diesel engine made by Sino-Germany Joint-venture Company in China. German DEUTZ Engine Company is a world famous engine manufacturer, with the technical improving, 226B series have been used and tested thousands of times in various mechanical and marine fields. German DEUTZ Engine Company has transfered all the facilities, technologies, management system to Shandong Weifang Diesel Engine Company, which is a Sino-Germany Joint-Venture Company with a capacity of manufacturing 226B series engine over 25,000 units per year. KH-D series deutz generator sets assembled by kaihua POWER have the features as follows: • The holistic sets can be installed conveniently as your need (Absorbers, fuel tank in base, muffle and internal starting battery are fixed as standard) • With all characters of German Engine: advanced technology, high reliability, long time service, low vibration, low noise (less than 85 db at 7 m ), small measurement and light weight. • The best price performance ratio, low running cost • Perfect control system is available to easy operation, comprehensive functions, reliable protection and so on.
|
Model |
Prime power |
Engine model |
No.of cyls |
Bore/stroke (mm) |
Fuel Cons. (L/hr) |
Dimension (L*W*H) (mm) |
Weight(kg) |
|
KW |
KVA |
|
Air-cooled Series |
|
KH-12GF |
12 |
15 |
F2L912 |
2 |
100/120 |
4 |
1400*800*1100 |
500 |
|
KH-20GF |
20 |
25 |
F3L912 |
3 |
100/120 |
4 |
1700*800*1100 |
700 |
|
KH-24GF |
24 |
30 |
F4L912 |
4 |
100/120 |
9.7 |
1900*800*1150 |
800 |
|
KH-36GF |
36 |
45 |
F4L912T |
4 |
102/125 |
9.7 |
2000*800*1150 |
950 |
|
KH-40GF |
40 |
50 |
F6L912 |
6 |
100/120 |
14.5 |
2250*800*1150 |
1150 |
|
KH-48GF |
48 |
60 |
F6L912T |
6 |
100/120 |
14.5 |
2250*800*1150 |
1200 |
|
KH-64GF |
64 |
80 |
BF6L913 |
6 |
102/125 |
24.9 |
2400*800*1250 |
1300 |
|
KH-76GF |
76 |
95 |
BF6L913C |
6 |
102/125 |
30.7 |
2500*800*1350 |
1500 |
|
Water-cooled Series |
|
KH-20GF |
20 |
25 |
D226B-3D |
3 |
105/120 |
6.5 |
1620*780*1200 |
780 |
|
KH-24GF |
24 |
30 |
D226B-3D |
3 |
105/120 |
6.5 |
1620*780*1200 |
780 |
|
KH-34GF |
34 |
42 |
TD226B-3D |
3 |
105/120 |
9.6 |
1620*780*1200 |
810 |
|
KH-48GF |
48 |
60 |
TD226B-4D |
4 |
105/120 |
13.6 |
1950*750*1650 |
950 |
|
KH-80GF |
80 |
100 |
TD226B-6D |
6 |
105/120 |
20.8 |
2230*840*1700 |
1210 |
|
KH-104GF |
104 |
130 |
TBD226B-6D |
6 |
105/120 |
26.4 |
2300*840*1740 |
1350 |
|
KH-120GF |
120 |
150 |
TBD226B-6D5 |
6 |
105/120 |
30.3 |
2300*840*1740 |
1450 |
|
KH-68GF |
68 |
85 |
BF4M1013E |
4 |
108/130 |
11.9 |
1920*740*1520 |
1150 |
|
KH-80GF |
80 |
100 |
BF4M1013EC |
4 |
108/130 |
14 |
2056*870*1472 |
1200 |
|
KH-104GF |
104 |
130 |
BF6M1013E |
6 |
108/130 |
17.5 |
2473*900*1546 |
1330 |
|
KH-121GF |
121 |
151 |
BF6M1013EC |
6 |
108/130 |
20.3 |
2473*900*1546 |
1330 |
|
KH-150GF |
150 |
188 |
BF6M1013FC |
6 |
108/130 |
28 |
2595*900*1546 |
1540 |
|
KH-165GF |
165 |
206 |
BF6M1013FC |
6 |
108/130 |
28 |
2595*900*1546 |
1540 |
|
KH-190GF |
190 |
237.5 |
BF6M1015 |
6 |
132/145 |
32.2 |
2453*1040*1822 |
1880 |
|
KH-260GF |
260 |
325 |
BF6M1015C |
6 |
132/145 |
44.1 |
3060*1315*2035 |
2300 |
|
KH-280GF |
280 |
350 |
BF6M1015C2 |
6 |
132/145 |
47.6 |
3060*1515*2035 |
2490 |
|
KH-300GF |
300 |
375 |
BF6M1015CP |
6 |
132/145 |
50.4 |
3060*1515*1095 |
2540 |
|
KH-345GF |
345 |
431 |
BF8M1015C |
8 |
132/145 |
60.4 |
3208*1515*1975 |
2870 |
|
KH-380GF |
380 |
475 |
BF8M1015C2 |
8 |
132/145 |
66.5 |
3208*1515*1975 |
2970 |
|
KH-400GF |
400 |
500 |
BF8M1015CP |
8 |
132/145 |
70.7 |
3200*1815*1978 |
3190 |
Note:1. Above that technical specifications are all 50Hz,rated voltage is 400/230V,the power factor is 0.8 (lag),and the connecting type is 3 phase and 4 wires.The 60Hz diesel generator sets can be supplied according to the customers' requirements. 2. Specifications may change without notice. |