IVECO aifo is not only a company specialize in producing diesel engines,respectively set up by Fiat Froup,but also one of the biggest manufacturer of the diesel engines in the world.F.I.A.T is founded in Turin,Italy on July 11, 1899. F.I.A.T has become one of the largest industrial groups in the world,which is ranked 49 among the world top 500 in 2003.And its products involve the cars,the commercial vehicles,the ships,the aerial products,the trans, the agricultural tractor,the architectural machines,the car components,the automated product line,the military vehicles and so on. F.I.A.T group has owned some famous brands,such as FIAT,FERRARI,IVECO AIFO,LANCIA,ALFA ROMEO,MASERATI CASE-NEWHOLL AND IVECO and so on.
|
Genset Model |
Prime Power(KW/KVA) |
Engine Model |
Cylinders (L/V) |
Bore/Stroke(mm) |
Fuel Cons. (g/KWh) |
Dimensions (L*W*H) (mm) |
Weight (kg) |
|
KH-16GF |
16/20 |
8031I06.05 |
3L |
104/115 |
225 |
1600*680*1085 |
720 |
|
KH-24GF |
24/30 |
8031I06.05 |
3L |
104/115 |
225 |
1600*680*1085 |
750 |
|
KH-32GF |
32/40 |
8041I06.55 |
4L |
104/115 |
227 |
1650*680*1085 |
855 |
|
KH-48GF |
48/60 |
NEF45SM1A |
4L |
104/132 |
210 |
2050*680*1350 |
1050 |
|
KH-60GF |
60/75 |
NEF45SM2A |
4L |
104/132 |
214 |
2050*680*1350 |
1050 |
|
KH-68GF |
68/85 |
NEF45TM1A |
4L |
104/132 |
205 |
2100*760*1380 |
1150 |
|
KH-80GF |
80/100 |
NEF45TM2A |
4L |
104/132 |
208 |
2100*800*1380 |
1230 |
|
KH-100GF |
100/125 |
NEF67SM1 |
6L |
104/132 |
208 |
2430*800*1620 |
1350 |
|
KH-110GF |
110/138 |
NEF67TM2A |
6L |
104/132 |
208 |
2550*825*1610 |
1440 |
|
KH-120GF |
120/150 |
NEF67TM3A |
6L |
104/132 |
212 |
2550*825*1610 |
1440 |
|
KH-160GF |
160/200 |
NEF67TE2A |
6L |
104/132 |
205 |
2710*820*1530 |
1730 |
|
KH-200GF |
200/250 |
CURSOR78TE2S |
6L |
115/125 |
193 |
2950*1050*1870 |
2380 |
|
KH-220GF |
220/275 |
CURSOR87TE1D |
6L |
117/135 |
205 |
3090*1055*1690 |
2560 |
|
KH-240GF |
240/300 |
CURSOR10TE1D |
6L |
125/140 |
192 |
3250*1055*1780 |
2680 |
|
KH-280GF |
280/350 |
CURSOR13TE2A |
6L |
135/150 |
188 |
3465*1055*1780 |
2850 |
|
KH-320GF |
320/400 |
CURSOR13TE3A |
6L |
135/150 |
208 |
3540*1270*1850 |
3100 |
|
KH-280GF |
580/720 |
VECTOR20TE2 |
8V |
145/152 |
198 |
3960*1560*2380 |
4800 |
Note:1. Above that technical specifications are all 50Hz,rated voltage is 400/230V,the power factor is 0.8(lag),and the connectingtype is 3 phase and 4 wires.The 60Hz diesel generator sets can be supplied according to the customers requirements. 2. Specifications may change without notice. |