|
MAN engines, under the same cubic capacity with much higher output power and much better environmental protection performance have been the representative particular for MAN generating sets application .They can satisfy with the harsh requirement of the generators and were developed under the newest technology study .This promised the absolute reliability , usability and economy during their operations .These are the strongpoint for those MAN generating sets manufactures and similar operators. In addition, MAN engines have much more merits to mention in the environmental protection aspect ,such like their gas exhaust and noise discharge are the best among those engines .Herein according to the comparatively strict environment law and regulation ,the diesel engine will play a very important role and those industrial department will benefit from the application of those high-speed diesel engines. The design of MAN diesel engine is light, strong power supply permanence application, low fuel consumption and can operating continuously. Thus as far as the engine is concerned, they showed many convinced merits for the customers. The MAN engines are developed and manufacture for generating power are D28 series (D2688,D2876, D2848, D2840, and D2842), D08 series are also available for small 6 cylinders engines .
|
Genset Model |
Prime Power
(KW/KVA) |
Engine Model |
Cylinders |
Bore/Stroke
(mm) |
Fuel Cons. (L/hr) |
Dimensions
(L*W* H) (mm) |
Weight (kg) |
|
KH-280GF |
280 / 350 |
D2866LE201 |
6 |
128/155 |
72 |
3100*1200*1850 |
2350 |
|
KH-320GF |
320 / 400 |
D2866LE203 |
6 |
128/155 |
76 |
3100*1200*1850 |
2600 |
|
KH-350GF |
350 / 438 |
D2876LE201 |
6 |
128/166 |
85 |
3200*1135*1954 |
2760 |
|
KH-400GF |
400 / 500 |
D2876LE203 |
6 |
128/166 |
85 |
3200*1135*1954 |
2760 |
|
KH-450GF |
450 / 563 |
D2848LE213 |
8 |
128/142 |
118 |
3140*1380*1995 |
3050 |
|
KH-450GF |
450 / 563 |
D2840LE201 |
10 |
128/142 |
108 |
3140*1180*1995 |
3050 |
|
KH-500GF |
500 / 625 |
D2840LE203 |
10 |
128/142 |
117 |
3140*1380*1995 |
3150 |
|
KH-550GF |
550 / 688 |
D2840LE213 |
10 |
128/142 |
145 |
3670*1400*1995 |
3880 |
|
KH-550GF |
550 / 688 |
D2842LE201 |
12 |
128/142 |
129 |
3670*1610*1995 |
3880 |
|
KH-600GF |
600 / 750 |
D2842LE203 |
12 |
128/142 |
138 |
3670*1610*1995 |
3950 |
|
KH-650GF |
650 / 813 |
D2842LE213 |
12 |
128/142 |
151 |
3670*1631*2010 |
3990 |
|
KH-800GF |
800 / 1000 |
D2862LE223 |
12 |
128/157 |
189 |
3750*1631*1950 |
4170 |
Note:1. Above that technical specifications are all 50Hz,rated voltage is 400/230V,the power factor is 0.8 (lag),and the connecting type is 3 phase and 4 wires.The 60Hz diesel generator sets can be supplied according to the customers' requirements. 2. Specifications may change without notice. |