Natural gas generator set is my company's recent launch of energy saving units. The genset has a surge of high precision, suitable for a wide range of dynamic performance, voltage wave abnormal small, high efficiency, compact structure, easy maintenance, reliable operation, long service life, economic performance is good.
|

Deutz Series |

Cummins Series

105(Ricardo) Series |
|
Model |
Prime power |
Engine model |
No.of cyls |
Bore/stroke (mm) |
Gas Cons. (m3/hr) |
Dimension (L*W*H) (mm) |
Weight(kg) |
|
KW |
KVA |
|
Cummins Series |
|
KH-30GF |
30 |
37.5 |
4BT3.9-T |
4 |
102/120 |
9 |
1800*800*1200 |
780 |
|
KH-40GF |
40 |
50 |
4BTA3.9-T |
4 |
102/120 |
13 |
1800*800*1220 |
800 |
|
KH-60GF |
60 |
75 |
4BTAA3.9-T |
4 |
102/120 |
18 |
1800*800*1220 |
890 |
|
KH-85GF |
85 |
106 |
6BTAA5.9-T |
6 |
102/120 |
28 |
2200*820*1400 |
1400 |
|
KH-120GF |
120 |
150 |
6CTAA8.3-T |
6 |
114/134 |
39 |
2500*850*1500 |
1850 |
|
KH-160GF |
160 |
200 |
MTAA11-T |
6 |
125/147 |
51 |
3050*1200*1750 |
3100 |
|
KH-200GF |
200 |
250 |
NTAA855-T |
6 |
140/152 |
66 |
3255*1050*1541 |
3550 |
|
KH-280GF |
280 |
350 |
KTAA19-T |
6 |
159/159 |
89 |
3443*1300*1916 |
4630 |
|
KH-400GF |
400 |
500 |
KTA38-T |
12 |
159/159 |
125 |
4525*1900*2310 |
8478 |
|
KH-550GF |
550 |
688 |
KTAA38-T |
12 |
159/159 |
178 |
4525*1900*2310 |
8760 |
|
Deutz Series |
|
KH-32GF |
32 |
40 |
TD226B-3D-T |
3 |
105/120 |
10 |
1900*788*1200 |
760 |
|
KH-43GF |
43 |
53.7 |
TD226B-4D-T |
4 |
105/120 |
14 |
1950*788*1400 |
860 |
|
KH-64GF |
64 |
80 |
TD226B-6D-T |
6 |
105/120 |
21 |
2200*788*1450 |
1230 |
|
KH-91GF |
91 |
113.7 |
TBD226B-6D-T |
6 |
105/120 |
29 |
2400*788*1450 |
1290 |
|
KH-158GF |
158 |
197.5 |
TBD234V6-T |
6 |
128/140 |
51 |
2710*1130*1710 |
2630 |
|
KH-211GF |
211 |
263.7 |
TBD234V8-T |
8 |
128/140 |
68 |
3020*1130*1710 |
3150 |
|
KH-316GF |
316 |
395 |
TBD234V12-T |
12 |
128/140 |
102 |
4170*1320*2015 |
5300 |
|
KH-388GF |
388 |
485 |
TBD604BL6-T |
6 |
170/195 |
125 |
4530*1505*2156 |
5600 |
|
KH-518GF |
518 |
647.5 |
TBD620V8-T |
8 |
170/195 |
167 |
4830*1716*2316 |
8500 |
|
KH-776GF |
776 |
970 |
TBD620V12-T |
12 |
170/195 |
250 |
5310*1716*2316 |
10500 |
|
KH-1035GF |
1035 |
1293.8 |
TBD620V16-T |
16 |
170/195 |
333 |
6035*1716*2395 |
13950 |
|
105 (Ricardo) Series |
|
KH-40GF |
40 |
50 |
R3105ZD-T |
3 |
105/120 |
13 |
1500*730*1200 |
800 |
|
KH-62GF |
62 |
77.5 |
R6105ZD-T |
6 |
105/120 |
20 |
2350*750*1540 |
1800 |
|
KH-78GF |
78 |
97.5 |
R6105ZLD-T |
6 |
105/120 |
25 |
2350*750*1540 |
1800 |
|
135 (Wudong) Series |
|
KH-160GF |
160 |
200 |
WDJ129TD16-T |
6 |
135/150 |
52 |
2700*900*1700 |
2700 |
|
KH-179GF |
179 |
223.8 |
WD145TAD30-T |
6 |
138/160 |
58 |
2700*900*1700 |
2700 |
|
KH-322GF |
322 |
403 |
WD258TD30-T |
12 |
135/150 |
104 |
3200*1400*2000 |
3800 |
|
KH-359GF |
359 |
448.8 |
WD287TAD58-T |
12 |
138/160 |
116 |
3500*1500*2000 |
4000 |
|
190 (Jichai) Series |
|
KH-446GF |
446 |
557.5 |
6190ZLC2-T |
6 |
190/210 |
144 |
6130*1760*2600 |
7370 |
|
KH-595GF |
595 |
743.8 |
8V190ZL-T |
8 |
190/210 |
191 |
5270*2040*2778 |
10700 |
|
KH-893GF |
893 |
1116.3 |
12V190ZL-T |
12 |
190/210 |
287 |
6190*2110*2800 |
12000 |
Note:1. Above that technical specifications are all 50Hz,rated voltage is 400/230V,the power factor is 0.8 (lag),and the connecting type is 3 phase and 4 wires.The 60Hz diesel generator sets can be supplied according to the customers' requirements. 2. Specifications may change without notice. |