Perkins Diesel Generator
Product Name: Perkins Diesel Generator

Product Code: 15959-674
Model: KH
Updated: 2010.05.12
Product From: Diesel generator-Taizhou Kaihua Diesel Generator Sets Co.,Ltd.
Views:
   Details

     

 

Perkins diesel generator set rated speed 1500rpm, four-stroke, water cooling fan, turbo, in the cold air, with ISO3046 standards, compact, power, high reliability and low cost of installation and maintenance costs, work Long cycle.

Excellent damping performance: computer-based simulation of the dynamic damping system optimized.

Advanced control system: Based on the reliability of the entire design of the monitoring system control strategy.

Environmental protecting, energy-saving and low-emission diesel generating units.

Low-noise: customerized muffler exhaust system.

Excellent performance: operational stability and vibration of small, fuel consumption rates, oil consumption rate is low and long operating life, overhaul a long time and low noise.

Model

Prime power

Engine model

No.of cyls

Bore/stroke
(mm)

Fuel Cons.
(L/h)

Dimension
(L*W*H) (mm)

Weight(kg)

KW

KVA

KH-7GF

7.2

9

403D-11G

4

77/81

2.2

1100*450*940

290

KH-10GF

10.4

13.1

403D-15G

3

84/90

3.2

1322*556*1260

396

KH-16GF

16.2

20.2

404D-22G

4

84/100

4.7

1322*556*1260

456

KH-24GF

24

30

1103A-33G

3

105/127

6

1770*715*1365

798

KH-36GF

36

45

1103A-33TG1

3

105/127

9.3

2148*750*1365

945

KH-48GF

48

60

1103A-33TG2

3

105/127

12.2

2148*750*1365

960

KH-75GF

75

93.7

1006TG1A

6

100/127

19

2512*735*1545

1180

KH-82GF

82

102.5

1006TG2A

6

100/127

19

2512*735*1545

1180

KH-109GF

109

136

1006TAG

6

100/127

28

2700*900*1458

1405

KH-120GF

120

150

1006TAG2

6

100/127

38

2700*900*1458

1410

KH-166GF

166

208

1306C-E87TAG3

6

116.6/135.9

42

2590*1005*1720

2006

KH-182GF

182

228

1306C-E87TAG4

6

116.6/135.9

45

2590*1005*1720

2080

KH-200GF

200

250

1306C-E87TAG6

6

116.6/135.9

48

2590*1005*1720

2135

KH-240GF

240

300

2206C-E14TAG1

6

137/165

63

3500*1150*2065

3240

KH-280GF

280

350

2206C-E14TAG2

6

137/165

72

3500*1150*2065

3309

KH-320GF

320

400

2206C-E14TAG3

6

137/165

81

3500*1150*2065

3309

KH-363GF

363

453

2506C-E15TAG1

6

145/183

90

4000*1125*2196

3800

KH-403GF

403

503

2506C-E15TAG2

6

145/183

99

3875*1150*2196

3945

KH-455GF

455

569

2506C-E15TAG3

6

145/183

108

3875*1150*2196

3945

KH-520GF

520

650

2806A-E18TAG2

6

145/183

122

3900*1470*2197

4706

KH-545GF

545

681

2806A-E18TAG3

6

145/183

135

3900*1470*2197

4706

KH-584GF

584

730

4006-23TAG2A

6

160/190

146

4290*1912*1760

6060

KH-640GF

640

800

4006-23TAG3A

6

160/190

160

4290*1912*2286

6260

KH-724GF

724

905

4008TAG1A

8

160/190

173

4940*1900*2250

7345

KH-818GF

818

1022

4008TAG2A

8

160/190

197

5030*1900*2250

7715

KH-1002GF

1002

1253

4012-46TWG2A

12

160/190

250

4635*2040*2308

9154

KH-1091GF

1091

1364

4012-46TWG3A

12

160/190

253

5295*2040*2308

10185

KH-1204GF

1204

1505

4012-46TAG2A

12

160/190

282

5295*2040*2308

10435

KH-1364GF

1364

1705

4012-46TAG3A

12

160/190

320

5295*2040*2308

10935

KH-1402GF

1402

1752

4016TAG

16

160/190

342

5928*2300*3010

15430

KH-1476GF

1476

1844

4016TAG1A

16

160/190

348

6010*2300*3010

15500

KH-1646GF

1646

2058

4016TAG2A

16

160/190

398

6010*2300*3010

15500

Note:1. Above that technical specifications are all 50Hz,rated voltage is 400/230V,the power factor is 0.8 (lag),and the connecting type is 3 phase and 4 wires.The 60Hz diesel generator sets can be supplied according to the customers' requirements.