Application

Low voltage generating systems

KAIHUA provides comprehensive solution for prime/standby power generation from 10-3000kva for low voltage generator systems.


KAIHUA diesel generator sets are widely used in mining, rental, railway, data center, and telecommunication projects.

KAIHUA is not only selling products, but care more about the best solution for the power service as well.

MEDIUM/ HIGH VOLTAGE GENERATING SYSTEMS

  • With the rapid development of the economic growth,more and more new data center power systems emerges and more power needs to be available to support growth and backup/emergency power supplies.

  • We are deliver the best available technology and support network offering industry-leading expertise.

  • KAIHUA Continuous power is used for applications where there is no utility power and the generator set is relied upon to supply a constant load for an unlimited number of hours annually such as remote power data center stations or co-location facilities.

  • KAIHUA provides a range of data center voltage solutions that have been used worldwide.

  • With the unquenchable thirst for more power, we are finding more data centers are considering medium voltage solutions that use a medium voltage alternator with the engines.

Advantages

-Facility staff are typically more comfortable interacting with low voltage generators.


-Low voltage equipment is much easier and quicker to source.


-Low voltage rental equipment can be used when needed.


-No medium voltage paralleling switchgear sections are required, resulting in a smaller footprint and significant cost savings

MARINE GENERATING SYSTEM

KAIHUA Cummins series marine Diesel generator sets have features of compact structure,  large power , low oil consumption , low discharge, low noise, reliable performances,  and long services life .Its professional service networks are spread across the country and world , which can provide 24 hours after service and assure the supplying of accessories in time .
  • Feature:

  • •Gen-set can use for Marine gen-set,  Marine emergency gen-set or Harbor gen-set.
    •We use the marine synchronouse Alternator with the brands of Stamford , Maraphon and Simens marine Alternator etc. Also can be supplied at the request of customers.
    •Parallel connection: Two and more normal marine generator sets can transfer loading without stoping , and can realize parallel.
    •Protection function :Thare are over-limit alarming for speed , oil pressure, cooling water temperature and oil temperature.
    •Can provide CCS, BV , ABS, DNV classification certificate.

GAS GENERATING SYSTEM

  • KAIHUA gas generator sets are designed according to the world environmental protection requirement and the new market environment. Natural gas generator set has the advantages of strong reliability of start and operation, advanced quality of output, lightweight, simple maintenance and low frequency noise.

  • Gas generator sets replace the traditional nonrenewable fuel, built for safer and convenient operation, cost efficiency, low pollution emission, and more suitable for electric installations, etc.

  • Baifa gas units are built according to different customer requirements, for years of research and development and the strict inspection, we are able to meet the different needs of each customer.

  • ISO3046, ISO4001 ISO8525, IEC34-1, GB1105, GB/T2820, CSH22-2, VDE & 0530 YD/T 502-2000 (communication special technical requirements of the gas generator).

1.Advanced and certified gas engines, specially designed for optimizing gas application. The design of the combustion chamber ensures the most efficient performance.


2.The alternator Made by world famous brand to maximize performance and reliability.


3.The mixed gas cooler Cooler has a large surface area to improve engine performance and heat utilization.

Application