Cummins Diesel Genset
As a specialist of Cummins Diesel Gense , Taizhou Kaihua Diesel Generator Sets Co., Ltd can offer you comprehensive selections of goods in this industry
Video
  • Cummins Diesel Genset
  • 50HZ
  • 60HZ
  • Service
  • Cummins series generating sets are persisting on integration and maximum efficiency for its products, as well as generating-sets are the optimum choice for users not only in standby field but also in prime field .Its excellent performance and incomparable reliability are leading to the best power solutions in power generating field.

  • Chongqing Cummins Engine Co.,Ltd mainly produce M,N,K series.

  • About Cummins Series Diesel Generator

  • Kaihua Cummins Series Diesel Generator are powered by Cummins engines,it enjoys the features of high reliability,easy maintenance,long continuous running hours .

  • KAIHUA has been working closely with Cummins diesel engine for many years. Now Kaihua is one of the best Cummins OEMs in China. The global service net of Cummins can provide our customers with reliable and guaranteed service.

  • Advantages of Cummins Diesel Generator

  • 1. International Warranty Service 2. Water cooled engine
    3. With ISO9001&CE certification
    4. Spare parts are easy to get from worldwide market with much cheaper price
    5. Coupled with Stamford alternator, Marathon alternator or Kaihua alternator
    6. Perfect after-service network
    7. Power range from 15kw to 2400kw, 50hz &60hz
    8. Rigorous test including 50% load, 75% load, 100% load and 110% load
    9. Very short delivery time

  • Standard Configuration of Cummins Open Type:

  • 1.Cummins engine
    2.Stamford/Marathon/Kaihua/Leroy Somer alternator
    3.Deep Sea, Smartgen,Comap control system
    4.Base fuel tank for option
    5.ABB,Schneider, Chint breaker
    6.Battery and battery switch
    7.Industrial silencer and flexible exhaust hose

Typical Orders

Genset Model

Standby Power

Prime power

Engine model

Dimension
(L×W×H) (mm)

Weight(kg)

KVA

KW

KVA

KW

DCEC CUMMINS SERIES

KH-20GF

28

22

25

20

4B3.9-G2

1660×750×1200

800

KH-24GF

33

26

30

24

4B3.9-G2

1660×750×1200

800

KH-32GF

44

35

40

32

4BT3.9-G2

1660×750×1200

810

KH-44GF

69

55

60

48

4BTA3.9-G2

1860×750×1200

850

KH-64GF

88

70

80

64

4BTA3.9-G11

2160×800×1300

1040

KH-75GF

110

88

100

80

6BT5.9-G2

2160×800×1300

1056

KH-100GF

125

100

115

92

6BTA5.9-G2

2160×800×1300

1096

KH-120GF

165

132

150

120

6BTAA5.9-G12

2300×850×1300

1400

KH-150GF

206

165

187.5

150

6CTA8.3-G2

2400×860×1380

1440

KH-180GF

248

198

225

180

6CTAA8.3-G2

2500×960×1450

1700

KH-200GF

275

220

250

200

6LTAA8.9-G2

2640×970×1450

2000

CCEC CUMMINS SERIES

KH-200GF

275

220

250

200

MTA11-G2A

2980×1000×1700

2320

KH-250GF

345

275

312.5

250

MTAA11-G3

3150×1050×1700

2450

KH-275GF

380

303

345

275

NTA855-G2A

3100×1000×1700

2600

KH-320GF

440

352

400

320

QSNT-G3

3400×1280×1800

3050

KH-360GF

495

396

450

360

KTA19-G3

3300×1350×2000

3600

KH-400GF

550

440

500

400

KTA19-G3A

3420×1250×1930

3720

KH-480GF

660

528

600

480

KTA19-G8

3550×1550×2100

4000

KH-500GF

688

550

625

500

KTAA19-G6A

3550×1550×2100

4400

KH-600GF

798

660

725

600

KTA38-G2

4260×1650×2350

6350

KH-640GF

880

704

800

640

KTA38-G2B

4260×1650×2350

6350

KH-720GF

990

792

900

720

KTA38-G2A

4350×1650×2350

6650

KH-800GF

1100

880

1000

800

KTA38-G5

4500×1850×2350

6900

KH-900GF

1238

990

1125

900

KTA38-G9

4500×2100×2500

7500

KH-1000GF

1375

1100

1250

1000

KTA50-G3

5100×2280×2500

9600

KH-1200GF

1650

1320

1500

1200

KTA50-GS8

5100×2280×2500

13000

IMPORTED CUMMINS SERIES

KH-380GF

500.5

400.4

475

364

QSX15-G6

3430×1200×2065

4100

KH-400GF

550

440

500

400

QSX15-G8

3430×1200×2065

4250

KH-500GF

687.5

550

625

500

VTA28-G5

4067×1880×2286

5450

KH-600GF

825

660

750

600

VTA28-G6

4047×1880×2286

5900

KH-640GF

880

704

800

640

QSK23-G3

4593×1562×2086

6200

KH-720GF

990

792

900

720

QST30-G3

4757×1702×2332

6500

KH-800GF

1100

880

1000

800

QST30-G4

4757×1800×2332

6700

KH-1500GF

2062.5

1650

1875

1500

QSK60-G3

6175×2600×2840

15152

KH-1600GF

2200

1760

2000

1600

QSK60-G4

6175×2600×2840

15366

KH-1800GF

2475

1980

2250

1800

QSK60-G13

6175×2600×2840

17217

Genset Model

Standby Power

Prime power

Engine model

Dimension
(L×W×H) (mm)

Weight(kg)

KVA

KW

KVA

KW

DCEC CUMMINS SERIES

KH-20GF

28

22

25

20

4B3.9-G2

1660×750×1200

800

KH-24GF

33

26

30

24

4B3.9-G2

1660×750×1200

800

KH-32GF

44

35

40

32

4BT3.9-G2

1660×750×1200

810

KH-44GF

69

55

60

48

4BTA3.9-G2

1860×750×1200

850

KH-64GF

88

70

80

64

4BTA3.9-G11

2160×800×1300

1040

KH-75GF

110

88

100

80

6BT5.9-G2

2160×800×1300

1056

KH-100GF

125

100

115

92

6BTA5.9-G2

2160×800×1300

1096

KH-120GF

165

132

150

120

6BTAA5.9-G12

2300×850×1300

1400

KH-150GF

206

165

187.5

150

6CTA8.3-G2

2400×860×1380

1440

KH-180GF

248

198

225

180

6CTAA8.3-G2

2500×960×1450

1700

KH-200GF

275

220

250

200

6LTAA8.9-G2

2640×970×1450

2000

CCEC CUMMINS SERIES

KH-200GF

275

220

250

200

NT855-GA

2980×1000×1700

2320

KH-250GF

345

275

312.5

250

NTA855-G1

3150×1050×1700

2450

KH-275GF

380

303

345

275

NTA855-G1B

3100×1000×1700

2600

KH-315GF

438

350

394

315

QSNT-G3

3400×1280×1800

3050

KH-360GF

495

396

450

360

KTA19-G2

3300×1350×2000

3600

KH-400GF

550

440

500

400

KTA19-G3

3420×1250×1930

3720

KH-480GF

660

528

600

480

KTAA19-G5

3550×1550×2100

4000

KH-500GF

688

550

625

500

KTAA19-G6A

3550×1550×2100

4400

KH-600GF

798

660

725

600

KT38-G

4260×1650×2350

6350

KH-700GF

963

770

875

700

KTA38-G1

4260×1650×2350

6350

KH-720GF

990

792

900

720

KTA38-G2

4350×1650×2350

6650

KH-800GF

1100

880

1000

800

KTA38-G2A

4500×1850×2350

6900

KH-900GF

1238

990

1125

900

KTA38-G4

4500×2100×2500

7500

KH-1000GF

1375

1100

1250

1000

KTA50-G3

5100×2280×2500

9600

KH-1200GF

1650

1320

1500

1200

KTA50-G9

5100×2280×2500

13000

IMPORTED CUMMINS SERIES

KH-380GF

500.5

400.4

475

364

QSX15-G6

3430×1200×2065

4100

KH-400GF

550

440

500

400

QSX15-G7

3430×1200×2065

4250

KH-500GF

687.5

550

625

500

QSK19-G4

4067×1880×2286

5450

KH-600GF

825

660

750

600

QSK19-G5

4047×1880×2286

5900

KH-640GF

880

704

800

640

QSK23-G2

4593×1562×2086

6200

KH-720GF

990

792

900

720

QST30-G3

4757×1702×2332

6500

KH-800GF

1100

880

1000

800

KTA38-G3

4757×1800×2332

6700

KH-1500GF

2062.5

1650

1875

1500

QSK50-G4

6175×2600×2840

15152

KH-1800GF

2475

1980

2250

1800

QSK60-G6

6175×2600×2840

17217

  • KAIHUA Service Teams are fast responsive to all you problem. Our distributor around the world receives extensive ongoing KAIHUA product training. This ensures that our service agent and distributor will correctly carry out service and with Baifa standard, it guarantees the service quality and outcome.

Pre-Sale Service

-The presale technical service for the customers

-Assist the conceptual design and selecting for the customers

-Assist the equipment room design and arrangement for the customers

-Accept the technical consultation of the customers



Sale of service

Kaihua will provide you with the production schedule to ensure the delivery quality of equipment.

Packing
Kaihua gensets are packed in plywood case as standard when exporting (except for those are in FCL)
Technical Support

Kaihua has a high effective team providing high-quality, all-round comprehensive professional services.

While maintain highly efficient and reliable to work 24/7 at site.


After Sales

-Equipment installation, debugging and operation

-The fire-fighting inspection testing
-The action and maintenance training for the users
-Remedy of the trouble and troubleshooting
-Offer OEM parts


Service Guarantee

-Set up usersrecord trail after service and termly check

-Organize centralized training for the operator of user

-Our staff can be on duty according to customers -requirement in special condition






Warranty

All Kaihua Product users will enjoy the hassle free. Every of our product is covered at least 1000 hours operation hours/ 12 month of warranty service.

Our service department will be full-responsibly and fast support to every technical issue, and provide solution to resume normal generator running. please call your local distributor or contact your sales manager.

Spare Parts


Original manufacturer authorized spare parts service and dealer

Rapid response in 24 hours global consignment



Product Catalog