Cummins Diesel Generators 3-3750 KVA | ISO & CE Certified

All Categories
Versatile Cummins Diesel Generator – Prime Power for Marine, Industrial & Mobile Use

Versatile Cummins Diesel Generator – Prime Power for Marine, Industrial & Mobile Use

Our Cummins diesel generator is a versatile solution, with outputs from 3-3750 KVA (land), 12-1250 KVA (marine), and 15-750 KVA (mobile). ISO, CE, and CCS certified, it boasts 30% efficiency improvement, a welded steel frame, and multi-parallel capability. Ideal for remote areas, shipping, and construction, it provides low-maintenance, energy-efficient power, backed by pre-sales technical support and after-sales troubleshooting for global clients.
Get A Quote

Why Choose Us

Authorized OEM Partnership & Proven Expertise

As an official OEM for Cummins, we integrate 22 years of generator manufacturing experience into every unit. Our deep cooperation with Cummins ensures authentic components and rigorous quality control, backed by ISO9001-2008, CE, CCS, and BV certifications, delivering reliable performance trusted by global clients.

Versatile Power Output for Diverse Scenarios

Our Cummins diesel generators cover 3-3,750 KVA (land use), 12-1,250 KVA (marine), and 15-750 KVA (mobile) ranges. We meet custom needs for voltage, frequency, soundproofing, and multi-parallel operation, ideal for industrial plants, marine vessels, construction sites, and emergency backup.

Comprehensive Support & Global Compatibility

Beyond quality products, we offer pre-sales technical consultation, custom design, and after-sales installation, training, and 24/7 troubleshooting. Our generators comply with international standards, enabling seamless integration in global projects, while our partnership with Cummins ensures easy access to spare parts and service networks worldwide.

Related Products

The cold weather starting capability and environmental adaptability of Cummins diesel generators are critical for operations in Arctic climates or high-altitude locations. These generators are equipped with a range of cold-start aids such as high-capacity battery banks, coolant and lube oil heaters, and air intake preheaters. For high-altitude operation, engines are derated according to standard charts and may feature specially calibrated turbochargers. A scientific research station in Antarctica relies on a 250 kVA Cummins generator with a polar package, including an enclosed and heated housing, to provide uninterrupted power for living quarters and sensitive scientific instruments in temperatures plunging below -50°C. A ski resort located at 3,000 meters above sea level uses a 400 kVA Cummins generator with appropriate altitude deration for standby power for its gondola lifts and resort facilities, ensuring skier safety and operational continuity during mountain storms that can disrupt the grid. A pipeline pumping station in Siberia uses Cummins generators equipped with jacket water heaters and thermostatically controlled radiator shutters to maintain optimal engine temperature for instant starting, even in the depths of winter. A telecommunications site on a mountaintop uses a compact 50 kVA Cummins generator with a high-altitude compensation kit, ensuring it can deliver its full rated power despite the thin air. For specific technical information on cold-weather packages, altitude deration tables, and pricing for generators configured for extreme environments, we invite you to contact our application engineering group for expert guidance and a formal quotation tailored to your environmental conditions.

Frequently Asked Questions

What certifications have your Cummins diesel generators obtained to ensure quality?

Our Cummins diesel generators hold multiple authoritative certifications, including ISO9001-2008 quality management system certification, CE, TLC, CCS, and BV. These certifications reflect rigorous technical verification, ensuring reliable performance trusted by 1000+ enterprises globally.
We offer versatile Cummins diesel generators with outputs: 3-3750 KVA (land use), 12-1250 KVA (marine), and 15-750 KVA (mobile). They suit industrial plants, marine vessels, construction sites, emergency backup, and remote areas, adapting to diverse voltage, frequency, and soundproofing needs.
Our Cummins diesel generators feature 30% improved efficiency, a welded steel bending beam frame for high strength and rigidity, and compact design (e.g., 1760x760x1380mm). They are low-maintenance, energy-efficient, and built to withstand harsh environments, ensuring long-term stable operation.

Related articles

Why are Cummins diesel generators good for industrial prime power?

26

Sep

Why are Cummins diesel generators good for industrial prime power?

Unmatched Reliability in Continuous Industrial Operations High Uptime Demands in Industrial Prime Power Settings Most industrial sites rely on Cummins diesel generators to keep their operations running almost constantly, aiming for that 99.95% uptime...
View More
How good is silent diesel generator’s noise reduction?

23

Oct

How good is silent diesel generator’s noise reduction?

Understanding the Core Principles of Diesel Generator Silent Operation Core Mechanism Behind Diesel Generator Silent Operation Modern silent diesel generators have come a long way from their noisy predecessors thanks to clever combinations of acous...
View More
How to choose 15-750KVA mobile generators for emergencies?

23

Oct

How to choose 15-750KVA mobile generators for emergencies?

Understanding Power Output and Sizing for Mobile GeneratorsCalculating Total Power Needs: Running vs. Starting WattageGetting the right size starts by knowing the difference between running watts (what something uses while operating) versus starting ...
View More
Are Perkins diesel generators reliable for long use?

23

Oct

Are Perkins diesel generators reliable for long use?

What Makes a Diesel Generator Reliable? The Perkins Engineering Advantage Reliability in diesel generators is defined by three core metrics: operational uptime, fuel efficiency, and annualized failure rates. A generator is considered "high-reliabil...
View More

Why Choose Us

Sophia Martinez

As a shipping company, we needed a durable generator for our cargo vessels. The 250 KVA marine Cummins generator (12-1250 KVA range) has withstood harsh sea conditions, including high humidity and rough waves. It meets CCS and BV certifications, complying with international maritime standards. The multi-parallel function allows us to combine two units for peak demand—absolutely reliable for long voyages.

Michael Chen

Our construction team uses the 150 KVA mobile Cummins diesel generator (15-750 KVA range) for remote projects. It’s easy to transport, sets up quickly, and runs efficiently on standard diesel. Over 18 months, we’ve only needed basic maintenance, thanks to its robust build quality. The pre-sales team helped customize the frequency to match our equipment, and spare parts are readily available when needed.

Robert Garcia

As an international engineering firm, we require generators that comply with global standards. The 1200 KVA Cummins diesel generator (3-3750 KVA range) has been deployed in 4 countries across Europe and Asia. It integrates perfectly with our existing systems, adapts to different voltage requirements, and the plywood packaging ensured damage-free shipping. The manufacturer’s partnership with Cummins guarantees authentic components, and on-site installation support was professional.

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
Why Choose Us?

Why Choose Us?

With 22 years of manufacturing expertise, we are an authorized OEM for Cummins and partner with top global brands. Our ISO, CE, CCS, and BV certified Cummins diesel generators cover 3-3750 KVA (land), 12-1250 KVA (marine), and 15-750 KVA (mobile) ranges, meeting custom voltage, soundproofing, and multi-parallel needs. We ensure reliable quality, efficient performance, and comprehensive pre-sales & after-sales support. Contact us today for tailored power solutions!
Facebook Facebook YouTube YouTube Linkedin Linkedin WhatsApp WhatsApp TopTop