Generator Diesel Cummins | Solution Potentiae Industrialis | Usque ad 45% Efficacia Combustibilis

Omnes Categorie

Cummins Diesel Generator

Caracteristicae structurales generatorum Cummins:
1. Plures sunt instructae cum systemate unicum PT combustibii (praeter series B et C);
2. Uti camera combustionis ω;
3. Sequitores campanarum rotatorii;
4. Plures viae olei et combustibii sunt installatae intra corpus cylindri et caput cylindri;
5. Tunica cylindrica humida cum treatment phosporization;
6. Axis crucis est factus e chalybe lege alloy, et iunctura axis est inductiva indurationis;
7. Prima sulcus anuli omnium pistillonum habet inserta ferri nigrum cum alia nickelis ad vitam meliorem praebendam.

Exemplum Genset Standby Power Potentia Prima Engine Model Dimensio (mm) Pondus(kg)
KVA KVA
KH-16GF 24 20 4B3.9-G11 1760*760*1380 700
KH-20GF 28 25 4B3.9-G1 1760*760*1380 730
KH-22GF 30 27.5 4B3.9-G1 1760*760*1380 900
KH-32GF 44 40 4BT3.9-G1 1760*760*1380 900
KH-48GF 65 60 4BTA3.9-G2 1760*760*1380 980
KH-50GF 70 62.5 QSB3.9-G2 1760*760*1380 1000
KH-58GF 80 72.5 4BTA3.9-G11 1760*760*1380 1030
KH-64GF 90 80 4BTA3.9-G11 1760*760*1380 1030
KH-64GF 90 80 QSB3.9-G3 1760*760*1380 1230
KH-75GF 103 94 6BT5.9-G1 2300*830*1700 1230
KH-80GF 110 100 6BT5.9-G2 2300*830*1700 1310
KH-80GF 110 100 QSB5.9-G2 2300*830*1700 1350
KH-92GF 125 115 6BTA5.9-G2 2300*830*1700 1320
KH-100GF 138 125 6BTAA5.9-G2 2350*830*1700 1360
KH-100GF 140 125 QSB5.9-G3 2350*830*1700 1360
KH-104GF 142 130 6BTAA5.9-G2 2350*830*1700 1360
KH-125GF 170 156 6BTAA5.9-G12 2390*860*1850 1360
KH-128GF 175 160 6CTA8.3-G1 2390*860*1850 1700
KH-144GF 200 180 6CTA8.3-G2 2390*860*1850 1720
KH-144GF 200 180 QSB6.7-G4 2500*960*1850 1800
KH-160GF 220 200 6CTAA8.3-G2 2450*960*1850 1800
KH-200GF 275 250 6LTAA8.9-G2 2500*960*1850 2060
KH-200GF 275 250 QSL8.9-G4 2500*1200*1850 2100
KH-240GF 330 300 6LTAA9.5-G1 2500*1160*1850 2200
KH-360GF 500 450 QSZ13-G3 3400*1258*2050 3030
KH-400GF 550 500 QSZ13-G10 3400*1258*2050 3130
KH-200GF 275 250 NT855-GA 3020*1100*1850 2350
KH-240GF 330 300 QSM11-G2 2500*1160*1850 2420
KH-248GF 340 310 MTAA11-G3 3020*1100*1850 2420
KH-256GF 350 320 NTA855-G1B 3020*1100*1850 2870
KH-275GF 375 344 NTA855-G2A 3020*1100*1850 2870
KH-280GF 388 350 NTA855-G4 3020*1100*1850 2870
KH-300GF 412 375 NTAA855-G7 3090*1100*1850 3100
KH-320GF 438 400 QSNT-G3 3090*1300*1850 3200
KH-320GF 450 NA NTAA855-G7A 3090*1100*1850 3100
KH-360GF 500 450 QSNT-G4X 3090*1300*1850 3300
KH-360GF 500 450 KTA19-G3 3400*1258*2050 4000
KH-400GF 550 500 KTA19-G3A 3400*1258*2050 4040
KH-400GF 550 500 KTA19-G4 3400*1258*2050 4200
KH-460GF 650 NA KTA19-G8 3650*1500*2050 4500
KH-460GF 650 575 KTAA19-G6 3650*1638*2050 4550
KH-500GF 688 625 KTA19-G8A 3650*1638*2050 4550
KH-500GF 688 NA KTAA19-G6A 3650*1638*2050 4550
KH-508GF 700 635 QSK19-G4 3650*1638*2050 4890
KH-520GF 715 650 QSK19-G4 3650*1638*2050 4950
KH-600GF 825 750 KTA38-G2 4550*2100*2320 6850
KH-640GF 880 800 KTA38-G2B 4550*2100*2320 7000
KH-728GF 1000 910 KTA38-G2A 4550*2100*2320 7150
KH-800GF 1100 1000 KTA38-G5 4750*2100*2320 7430
KH-900GF 1250 NA KTA38-G9 4750*2100*2320 7800
KH-1000GF 1375 1250 QSK38-G5 5000*2200*2500 7900
KH-1000GF 1375 1250 KTA50-G3 5000*2200*2500 9600
KH-1120GF 1540 1400 KTA50-G8 5820*2200*2800 11000
KH-1200GF 1650 1500 KTA50-GS8 5820*2200*2800 11000
KH-1340GF 1875 1675 KTA50-G15A 5820*2200*2800 11300
KH-1500GF 2000 1875 KTA50-G16A 5820*2200*2800 11400
KH-1640GF 2250 2050 QSK60-G4 5820*2200*2800 15500
KH-1800GF 2500 2250 QSK60-G8 5820*2200*2800 16000
KH-2000GF 2750 2500 QSK60-G23 5820*2200*2800 16500
Exemplum Genset Standby Power Potentia Prima Engine Model Dimensio (mm) Pondus(kg)
KVA KVA
KH-24GF 33 30 4B3.9-G2 1760*760*1380 730
KH-36GF 50 45 4BT3.9-G2 1760*760*1380 900
KH-50GF 68 62.5 4BTA3.9-G2 1760*760*1380 980
KH-52GF 70 65 4BTA3.9-G2 1760*760*1380 980
KH-56GF 77 70 4BTA3.9-G11 1760*760*1380 1000
KH-68GF 95 85 4BTA3.9-G11 1760*760*1380 1040
KH-72GF 100 90 4BTA3.9-G11 1760*760*1380 1080
KH-88GF 120 110 6BT5.9-G2 2300*830*1700 1310
KH-96GF 132 120 6BT5.9-G2 2300*830*1700 1330
KH-104GF 145 130 6BTA5.9-G2 2300*830*1700 1330
KH-116GF 156 145 6BTAA5.9-G2 2350*830*1700 1360
KH-134GF 180 168 6BTAA5.9-G12 2390*860*1850 1360
KH-160GF 212 200 6CTA8.3-G2 2390*860*1850 1720
KH-184GF 250 230 6CTAA8.3-G2 2450*960*1850 1720
KH-200GF 275 250 6LTAA8.9-G2 2500*960*1850 2060
KH-224GF 306 280 6LTAA8.9-G3 2500*960*1850 2060
KH-240GF 330 300 6LTAA9.5-G1 2500*1060*1850 2400
KH-368GF 500 460 QSZ13-G3 3400*1258*2050 3030
KH-248GF 344 310 NTA855-G1 3020*1100*1850 2770
KH-275GF 375 344 NTA855-G1B 3020*1100*1850 2870
KH-320GF 435 400 NTA855-G3 3020*1100*1850 3000
KH-350GF 500 438 KTA19-G2 3400*1258*2050 4000
KH-400GF 550 500 KTA19-G3 3400*1258*2050 4000
KH-410GF 562 512 KTA19-G3 3400*1258*2050 4000
KH-450GF 625 562 KTA19-G3A 3400*1258*2050 4040
KH-450GF 625 562 KTA19-G4 3400*1258*2050 4040
KH-550GF 750 NA KTAA19-G6A 3650*1638*2050 4550
KH-550GF 750 688 QSK19-G5 3650*1638*2050 4890
KH-620GF 850 775 KT38-G 4550*2100*2320 6850
KH-728GF 1000 910 KTA38-G2 4550*2100*2320 7000
KH-800GF 1100 1000 KTA38-G2A 4550*2100*2320 7150
KH-900GF 1250 1125 KTA38-G4 4750*2100*2320 7430
KH-1000GF 1375 NA KTA38-G9 5000*2200*2500 7800
KH-1130GF 1562 1420 KTA50-G3 5000*2200*2500 9600
KH-1280GF 1875 1600 KTA50-G9 5820*2200*2800 11300
KH-1824GF 2500 2280 QSK60-G6 5850*2200*2800 16000
Turmae Servitii KAIHUA celeriter respondent ad omnia tua problemata. Distributores nostri per orbem terrarum amplam continuatam institutionem productorum KAIHUA accipiunt. Hoc efficit ut agens servitii et distributores nostros recte servitium peragant et cum norma Baifa, id garantat qualitatem et eventum servitii.
Servitium Prae-venditionis
fb38060c-c2b8-4edd-8105-f9ba2a8f13c9.jpg
-Servitium technicum praesale pro clientibus
-Auxilium in consilio conceptuali et selectione pro clientibus
-Auxilium in consilio et dispositione cubiculorum apparatum pro clientibus
-Accipere consultationem technicam clientium
Venditio servitii
1704444712983147.jpg
Kaihua te praebebit schedula productionis, ut partus qualitas instrumenti conservet.
Sarcina
DSC00519.JPG
Kaihua genseta in casu ligni multiplexi ut norma cum exportando sarcinantur (nisi quae in FCL sunt)
Supportus Technicus
1704444876659720.jpg
Kaihua habet altam efficacem turmam praebentem altae qualitatis, universales comprehensivas professionales servitia.
Dum altam efficientiam et fiduciam servat ad laborandum 24/7 in situ.
Post Sales
1704444994960856.jpg
-Apparatus institutio, debugging et operatio
-Inspectio ignis probatio
-Actio et sustentatio disciplina pro usoribus
-Remedium difficultatis et troubleshooting
-Partes OEM offerre
Servitium Securitatis

1704445039377431.jpg

-Constituere usorum recordum post servitium et periodice examinare
-Organizare centralizatum disciplinam pro operatore usoris
-Nostri operarii secundum exigentiam emptoris in speciali condicione in officio esse possunt
Cautionis Tempus
Omnes usores Productorum Kaihua sine difficultate fruentur. Unumquodque nostrum productum saltem 1000 horas operationis/ 12 menses servitii warantiae tegitur.
Nostrum servitium department plenam responsabilitatem et celerem subsidium ad omnem quaestionem technicam praebebit, et solutionem ad normalem generatoris operationem resumendam praebebit. quaeso voca tuum distributorem localem vel contactum tuum venditionis procuratorem.
Parce partes
Originalis fabricatoris partes sparsas servitium et mercator
Celer responsio in 24 horis globali consignment

Libet pretium gratis accipere

Noster moderator mox te contactabit.
Email
Nomen
Societas Nomen
Dictum
0/1000
Facebook Facebook Youtube Youtube Linkedin Linkedin WhatsApp WhatsApp SummumSummum