Generator Diesel Shangchai | Solution Potentiae Industrialis | Certificatus ISO

Omnes Categorie

Shangchai (SDEC) Diesel Generator

Caracteristicae structurae generatorum Shangchai:
1. Crankshaft integralis, corpus gantridum, virga conjunctiva plana, pistillum breve, species compacta et ratio, apta ad coniunctionem, quae cum veteri motoris dieselici 135 commutari potest;
2. Camera combustionis collari novo utitur ut pressionem injectionis olei augeat, processum combustionis melioret, et normas environmentalis satisfaciat: valor pollutantium emissionis exhalationis requisitionibus JB8891-1999 congruit, et sonitus requisitionibus GB14097-1999 cum margine congruit;
3. Systema lubricationis et refrigerationis optime designatum est, numerum tubulorum externorum et partium minuit, et alternator sine pulvere integrum utitur, qui tres fuga magnopere meliorat et firmitatem magnopere augent.
4. Conjugatur cum turbo compressoribus J98 et J114b, qui habent robustam operationem in regionibus montanis. Cum utuntur in regionibus montanis altitudine 5000m, decrementum potentiae est minus quam 3%;

Exemplum Genset Standby Power Potentia Prima Engine Model Dimensio (mm) Pondus(kg)
KVA KVA
KH-8GF 11 10 3Z1.1-G42 1350*600*1100 550
KH-10GF 14 13 3ZT1.1-G42 1350*600*1100 600
KH-12GF 17 15 4Z2.3-G21 1350*600*1100 610
KH-16GF 22 20 4Z2.7-G21 1450*600*1100 630
KH-25GF 34 31 4Z3.2-G21 1500*600*1100 700
KH-32GF 44 40 4ZT3.2-G21 1500*600*1100 750
KH-40GF 55 50 4ZT3.5-G21 1600*600*1100 760
KH-50GF 69 63 SC4H95D2 1910*900*1170 940
KH-64GF 88 80 SC4H115D2 1910*900*1170 970
KH-80GF 110 100 SC4H140D2 2100*890*1260 1040
KH-90GF 124 113 SC4H160D2 2100*890*1260 1060
KH-100GF 138 125 SC4H180D2 2100*890*1260 1080
KH-120GF 165 150 SC7H205D2 2500*890*1400 1500
KH-150GF 207 188 SC7H250D2 2500*950*1440 1540
KH-160GF 220 200 SC8D280D2 2520*980*1500 1560
KH-180GF 247 225 SC9D310D2 2600*1050*1550 1800
KH-200GF 275 250 SC9D340D2 2750*1060*1500 2650
KH-250GF 344 313 SC13G420D2 3110*1280*1750 2870
KH-280GF 385 350 SC12E460D2 3180*1100*1600 2900
KH-300GF 413 375 SC15G500D2 3150*1280*1750 2930
KH-320GF 440 400 SC13E550D2 3250*1400*1750 2980
KH-400GF 550 500 6ETAA12.8-G310 3250*1280*1750 3000
KH-450GF 619 563 SC27G755D2 3550*1400*2000 4450
KH-500GF 688 625 SC27G830D2 3550*1520*1970 4500
KH-550GF 757 688 SC27G900D2 3610*1520*2060 4600
KH-600GF 825 750 6KTAA25-G32 3800*1600*2150 4700
KH-660GF 908 825 6KTAA25-G31 3800*1600*2150 4800
KH-720GF 990 900 6KTAA25-G320 4390*1600*2100 5800
KH-800GF 1100 1000 6KTAA25-G321 4390*1600*2100 5860
KH-900GF 1238 1125 6WTAA35-G310 4600*1800*2400 7200
KH-1000GF 1375 1250 6WTAA35-G311 4600*1800*2400 7300
KH-1100GF 1513 1375 12KTA58-G36 4400*2200*2510 7340
KH-1250GF 1719 1563 12KTA58-G35 4550*2200*2510 7360
KH-1350GF 1857 1688 12KTA58-G34 4550*2200*2510 7380
KH-1500GF 2063 1875 12KTA58-G33 4550*2200*2510 7400
KH-1600GF 2200 2000 12KTA58-G32 4650*2200*2510 7420
KH-1800GF 2475 2250 12KTA58-G31 4650*2450*2510 7440
Exemplum Genset Standby Power Potentia Prima Engine Model Dimensio (mm) Pondus(kg)
KVA KVA
KH-8GF 11 10 3Z1.1-G42 1350*600*1100 550
KH-10GF 14 13 3ZT1.1-G42 1350*600*1100 600
KH-12GF 17 15 4Z2.3-G21 1350*600*1100 610
KH-16GF 22 20 4Z2.7-G21 1450*600*1100 630
KH-25GF 34 31 4Z3.2-G21 1500*600*1100 700
KH-32GF 44 40 4ZT3.2-G21 1500*600*1100 750
KH-40GF 55 50 4ZT3.5-G21 1600*600*1100 760
KH-50GF 69 63 4HT4.3-G22 1910*900*1170 940
KH-64GF 88 80 4HT4.3-G23 1910*900*1170 970
KH-80GF 110 100 4HTAA4.3-G21 2100*890*1260 1040
KH-90GF 124 113 4HTAA4.3-G23 2100*890*1260 1060
KH-100GF 138 125 4HTAA4.3-G22 2100*890*1260 1080
KH-120GF 165 150 6HTAA6.5-G22 2500*890*1400 1500
KH-150GF 207 188 6HTAA6.5-G23 2500*950*1440 1540
KH-160GF 220 200 6DTAA8.9-G21 2520*980*1500 1560
KH-180GF 247 225 6DTAA8.9-G24 2600*1050*1550 1800
KH-200GF 275 250 6DTAA8.9-G23 2750*1060*1500 2650
KH-250GF 344 313 6ETAA11.8-G22 3110*1280*1750 2870
KH-280GF 385 350 6ETAA11.8-G21 3180*1100*1600 2900
KH-300GF 413 375 6ETAA12.8-G22 3150*1280*1750 2930
KH-320GF 440 400 6ETAA12.8-G32 3250*1400*1750 2980
KH-400GF 550 500 6ETAA12.8-G310 3250*1280*1750 3000
KH-450GF 619 563 6KTAA25-G310 3550*1400*2000 4450
KH-500GF 688 625 6KTAA25-G39 3550*1520*1970 4500
KH-550GF 757 688 6KTAA25-G38 3610*1520*2060 4600
KH-600GF 825 750 6KTAA25-G32 3800*1600*2150 4700
KH-660GF 908 825 6KTAA25-G31 3800*1600*2150 4800
KH-720GF 990 900 6KTAA25-G320 4390*1600*2100 5800
KH-800GF 1100 1000 6KTAA25-G321 4390*1600*2100 5860

Turmae Servitii KAIHUA celeriter respondent ad omnia tua problemata. Distributores nostri per orbem terrarum amplam continuatam institutionem productorum KAIHUA accipiunt. Hoc efficit ut agens servitii et distributores nostros recte servitium peragant et cum norma Baifa, id garantat qualitatem et eventum servitii.
Servitium Prae-venditionis

fb38060c-c2b8-4edd-8105-f9ba2a8f13c9.jpg
-Servitium technicum praesale pro clientibus
-Auxilium in consilio conceptuali et selectione pro clientibus
-Auxilium in consilio et dispositione cubiculorum apparatum pro clientibus
-Accipere consultationem technicam clientium
Venditio servitii

1704444712983147.jpg
Kaihua te praebebit schedula productionis, ut partus qualitas instrumenti conservet.
Sarcina

DSC00519.JPG
Kaihua genseta in casu ligni multiplexi ut norma cum exportando sarcinantur (nisi quae in FCL sunt)
Supportus Technicus

1704444876659720.jpg
Kaihua habet altam efficacem turmam praebentem altae qualitatis, universales comprehensivas professionales servitia.
Dum altam efficientiam et fiduciam servat ad laborandum 24/7 in situ.
Post Sales

1704444994960856.jpg
-Apparatus institutio, debugging et operatio
-Inspectio ignis probatio
-Actio et sustentatio disciplina pro usoribus
-Remedium difficultatis et troubleshooting
-Partes OEM offerre
Servitium Securitatis

1704445039377431.jpg
-Constituere usorum recordum post servitium et periodice examinare
-Organizare centralizatum disciplinam pro operatore usoris
-Nostri operarii secundum exigentiam emptoris in speciali condicione in officio esse possunt
Cautionis Tempus
Omnes usores Productorum Kaihua sine difficultate fruentur. Unumquodque nostrum productum saltem 1000 horas operationis/ 12 menses servitii warantiae tegitur.
Nostrum servitium department plenam responsabilitatem et celerem subsidium ad omnem quaestionem technicam praebebit, et solutionem ad normalem generatoris operationem resumendam praebebit. quaeso voca tuum distributorem localem vel contactum tuum venditionis procuratorem.
Parce partes
Originalis fabricatoris partes sparsas servitium et mercator
Celer responsio in 24 horis globali consignment

Libet pretium gratis accipere

Noster moderator mox te contactabit.
Email
Nomen
Societas Nomen
Dictum
0/1000
Facebook Facebook Youtube Youtube Linkedin Linkedin WhatsApp WhatsApp SummumSummum