Volvo generatorlarining konstruktiv xususiyatlari:
1. Tez va ishonchli suzmasdan ishga tushish kuchini;
2. Afiyoning va kuchli yuk kapatsitatini;
-Turbo ladashi texnologiyasi ishlatiladi, motor inertsiasi past;
-Elektronik regulator yong'ajni boshqaradi va tez javob beradi;
-Og'ir yuk ostida minimal ta'sir vaqtida;
3. Ishonchalı quvvat chiqishi;
4. Sifatli qism lar asosida ishonchli va ilojiy ishlash;
5. Motor oqilsiz ishlaydi;
6. Kichik dizel sariqi sarf etish, past ishlov va remont narxi;
7. Ichki ovoz dizayni motor ovozini past qilish uchun;
-Past ovozli dizayn;
-Afiyoning silindir sinovligi;
-Optimallashtirilgan dam olib tashlash dizayni;
-Aniq va mos keluvchi turbo ladash;
-Past tezlikdagi ventilyator;
8.Kompakt struktura va portativ og'irligi;
9.Dunyo bo'yicha boshqa brandlarga nisbatan, shu mayda / cho'qqi bilan generator seti yuqori balanslangan oruqli va ko'proq quvvat chiqishi ;
10.Mukammal ishlov berish natijasi.
| Genset modeli | Rezerv energiyasi | Bosh qudrat | Motor modeli | O'lchamlar (mm) | Vazn(kg) |
| KVA | KVA | ||||
| KH-68GF | 94 | 85 | TAD530GE | 1840*900*1550 | 1290 |
| KH-80GF | 109 | 100 | TAD531GE | 2150*900*1550 | 1350 |
| KH-104GF | 142 | 130 | TAD532GE | 2150*900*1550 | 1400 |
| KH-120GF | 165 | 150 | TAD731GE | 2410*930*1650 | 1820 |
| KH-150GF | 206 | 188 | TAD732GE | 2550*930*1670 | 1820 |
| KH-160GF | 220 | 200 | TAD733GE | 2550*930*1670 | 1820 |
| KH-160GF | 220 | 200 | TAD840GE-B | 2700*1050*1610 | 2000 |
| KH-200GF | 275 | 250 | TAD734GE | 2580*930*1670 | 2100 |
| KH-200GF | 275 | 250 | TAD841GE | 2580*930*1670 | 2100 |
| KH-240GF | 330 | 300 | TAD842GE | 3100*1120*1788 | 2300 |
| KH-250GF | 346 | 315 | TAD1341GE | 3100*1120*1788 | 2350 |
| KH-260GF | 358 | 325 | TAD843GE | 3100*1120*1788 | 2400 |
| KH-280GF | 385 | 350 | TAD1342GE | 3100*1120*1788 | 2770 |
| KH-300GF | 415 | 380 | TAD1343GE | 3100*1120*1788 | 2900 |
| KH-328GF | 450 | 410 | TAD1344GE | 3100*1120*1788 | 3000 |
| KH-360GF | 500 | 450 | TAD1345GE | 3100*1120*1788 | 3200 |
| KH-400GF | 550 | 500 | TAD1346GE | 3100*1120*1788 | 3250 |
| KH-400GF | 550 | 500 | TAD1641GE | 3400*1270*1974 | 3500 |
| KH-480GF | 660 | 600 | TAD1642GE | 3400*1270*1974 | 3610 |
| KH-500GF | 688 | 625 | TWD1643GE | 3400*1400*2100 | 4050 |
| KH-500GF | 688 | 625 | TWD1644GE | 3400*1400*2100 | 4100 |
| KH-520GF | 720 | 650 | TWD1644GE | 3400*1400*2100 | 4100 |
| KH-560GF | 770 | 700 | TWD1645GE | 3400*1400*2100 | 4100 |
| KH-600GF | 825 | 750 | TWD1744GE | 3400*1400*2100 | 4200 |
| Genset modeli | Rezerv energiyasi | Bosh qudrat | Motor modeli | O'lchamlar (mm) | Vazn(kg) |
| KVA | KVA | ||||
| KH-104GF | 145 | 131 | TAD532GE | 2150*900*1550 | 1400 |
| KH-160GF | 220 | 200 | TAD732GE | 2550*930*1670 | 1820 |
| KH-178GF | 248 | 223 | TAD733GE | 2550*930*1670 | 1820 |
| KH-180GF | 250 | 225 | TAD840GE-B | 2550*930*1670 | 2000 |
| KH-208GF | 286 | 260 | TAD734GE | 2600*1120*1761 | 2000 |
| KH-208GF | 286 | 260 | TAD841GE | 2600*1120*1761 | 2100 |
| KH-240GF | 330 | 300 | TAD842GE | 3100*1120*1788 | 2400 |
| KH-272GF | 375 | 340 | TAD1341GE | 3100*1120*1788 | 2350 |
| KH-256GF | 352 | 320 | TAD843GE | 3100*1120*1788 | 2500 |
| KH-320GF | 440 | 400 | TAD1342GE | 3100*1120*1788 | 2770 |
| KH-328GF | 450 | 410 | TAD1343GE | 3100*1120*1788 | 2900 |
| KH-364GF | 500 | 455 | TAD1344GE | 3100*1120*1788 | 3000 |
| KH-456GF | 642 | 570 | TAD1641GE | 3400*1270*1974 | 3500 |
| KH-410GF | 564 | 512 | TAD1346GE | 3100*1120*1788 | 3210 |
| KH-500GF | 688 | 625 | TAD1642GE | 3400*1270*1974 | 3610 |
| KH-550GF | 750 | 688 | TWD1643GE | 3400*1400*2100 | 4100 |
| KH-550GF | 752 | 684 | TWD1644GE | 3400*1400*2100 | 4100 |
| KH-580GF | 800 | 725 | TWD1673GE | 3400*1400*2100 | 4100 |
| KH-640GF | 880 | 800 | TWD1744GE | 3600*1400*2100 | 4200 |
KAIHUA Xizmat Komandalari sizning barcha muammolaringizga tez javob beradi. Dunyo bo'ylab bizning distributory doimiy KAIHUA mahsulotlari bo'yicha o'qituviga ega. Bu, xizmat agentlarimiz va distributoryning xizmatni to'g'ri amalga oshirishini ta'minlaydi va Baifa standarti bilan, xizmat sifatini va natijani ta'minlaydi.
Oldindan sotish xizmati

-Sotuv oldidan mavjud texnik xizmat
-Mijozlar uchun tushuntiruvli dizayn va tanlovni bajarish
-Mijozlar uchun jihoz xonasi dizaynini va tartibini yordam berish
-Mijozlardan texnik maslahat olish
Xizmat sotishi

Kaihua sizga yetkazib berish sifatini ta'minlash uchun jihoz ish jadvalini taqdim etadi.
Qadoqlash
Kaihua generatorlar eksport qilinishi paytida plyudabrda standard bo'lib paketlanadi (FCL larni nüqtadan olib tashlab)
Техник қўллаб-қувватлаш

Kaihua sifatli, jihohdo komprehsiv va professonal xizmatlarni taqdim etish uchun baland efektda ishlaydigan jamoa egadir.
24/7 reja bo'yicha ish joyida baland samarali va ishonchli ishlaydi.
Sotuvdan keyin

-Jihoz o'rnatish, debag va ishlaydi
-Atrof-muhit sinov testi
-Foydalanuvchilar uchun harakat va xizmatlash turini o‘rganish
-Xato tuzatish va muammolarni hal etish
-OEM qismalarini taklif etish
Xizmat kafolati

-Xizmatdan keyin va muddatli tekshiruvdan so‘ng foydalanuvchilar tarixini belgilash
-Foydalanuvchining operatori uchun markaziy ta’limni tashkil etish
-Maxsus shartlarda bizning xodimlar mijozning talabiga ko‘ra vazifada bo‘lishi mumkin
Kafolat
Barcha Kaihua mahsulotlari foydalanuvchilari aksizlik bilan ega bo‘ladi. Bizning har bir mahsuloti kamida 1000 soat ishlaydi/ 12 oy garantiya xizmati bilan qoplangan.
Xizmat bo‘limimiz har bir texnik muammosiga to‘llantirilmagan va tez qo‘llab-quvvatlashni taminlaydi, va normal generator ishlashini davom ettirish uchun yechim beradi. Iltimos, mahalliy distributorgingizni chaqiring yoki savdo menejerингиз билан bog'laning.
Ehtiyot qismlar
Asal ishlab chiqaruvchi yetkazib berilgan asli qism xizmati va sotuvchi
24 soat ichida tez javob va jahon bo‘ylab yetkazib berish