Yuchai generatorlarining konstruktiv xususiyatlari:
1. Dvigatel aloy materialdan iborat konkav-konvex blokdan iborat, u holda ikki tomondan sabqlangan quti bor, bu rigidity va daraxt solishtirish performansini yanada yuqori sathaga olib keladi, blokning o'rtasida qo'shimcha qutu o'rnatilgan, bu esa o'rnatishni ishonchli qiladi.
2. Blok ichida qurilgan yordamchi, pistonli jarayonlarni davom etish orqali sochilayotgan maxsus burchak suhbatidan o'tkaziladi, bu harorat yukini aks ettirish imkoniyatini ta'minlaydi.
3. Patentlangan optimallashtirilgan dizayn bilan mo'ljallangan valik asosiy qismi, yangi turdagi silikon tirtakli burkilish damperi bilan moslashtirilgan, bu diesel dvigatelini aniq ishlashini ta'minlaydi.
4. Diesel dvigateli nazorat vositasi va xavf xabar beruvchi qurilma bilan moslashtirilgan, bu suv harorati, maslo harorati, maslo bosimi va tezlik ortishi bo'yicha avtomatik alarm va xavf xabar beruvchi to'xtatishni amalga oshirishi mumkin.
5. Motor bloki va integrallashgan laminali metall krankshafti va allow cast ironi bo‘lgan silindir qalqasi, kichik hajmda, yaxshi og‘irligida va oson vaznida, yuqori ishonchli.
Yuchai T2(50Hz) orqali ishlaydi
| Genset modeli | Rezerv energiyasi | Bosh qudrat | Motor modeli | O'lchamlar (mm) | Vazn(kg) |
| KVA | KVA | ||||
| KH-20GF | 28 | 25 | YCD4V12D-35 | 1700*700*1050 | 600 |
| KH-32GF | 44 | 40 | YCD4V22D-55 | 1700*700*1100 | 650 |
| KH-36GF | 50 | 45 | YC4D60-D25 | 1810*780*1120 | 740 |
| KH-50GF | 69 | 63 | YC4D90Z-D25 | 1900*750*1120 | 780 |
| KH-64GF | 88 | 80 | YC4A100Z-D25 | 1950*770*1230 | 1040 |
| KH-80GF | 110 | 100 | YC4A140L-D25 | 2150*850*1250 | 1180 |
| KH-94GF | 129 | 117 | YC4A180L-D20 | 2320*900*1280 | 1250 |
| KH-108GF | 150 | 136 | YC6B180L-D20 | 2430*900*1280 | 1320 |
| KH-125GF | 173 | 157 | YC6B205L-D20 | 2430*900*1280 | 1350 |
| KH-150GF | 206 | 188 | YC6A245L-D21 | 2490*960*1400 | 1500 |
| KH-213GF | 294 | 267 | YC6MK350L-D20 | 2970*1125*1630 | 2060 |
| KH-255GF | 351 | 319 | YC6MK420L-D20 | 2970*1125*1630 | 2240 |
| KH-292GF | 401 | 365 | YC6MJ500L-D21 | 3060*1125*1650 | 2350 |
| KH-334GF | 460 | 418 | YC6T600L-D22 | 3450*1240*1868 | 3380 |
| KH-364GF | 501 | 456 | YC6T600L-D22 | 3520*1240*1868 | 3490 |
| KH-400GF | 550 | 500 | YC6T660L-D20 | 3520*1240*1868 | 3620 |
Yuchai T3(50Hz) orqali ishlaydi
| Genset modeli | Rezerv energiyasi | Bosh qudrat | Motor modeli | O'lchamlar (mm) | Vazn(kg) |
| KVA | KVA | ||||
| KH-16GF | 23 | 20 | YCDV254FHZ-25 | 1300*550*900 | 450 |
| KH-20GF | 28 | 25 | YCDV254FHZ-35 | 1340*550*900 | 480 |
| KH-24GF | 33 | 30 | YCDV254FHZ-40 | 1400*550*930 | 530 |
| KH-32GF | 44 | 40 | YCDV254FHZ-50 | 1450*550*930 | 550 |
| KH-40GF | 55 | 50 | YC4D80-D34 | 1800*750*1140 | 760 |
| KH-45GF | 63 | 56 | YC4D80-D34 | 1890*750*1140 | 790 |
| KH-50GF | 70 | 63 | YC4D90-D34 | 1890*750*1140 | 790 |
| KH-58GF | 80 | 73 | YC4D105-D34 | 1890*750*1140 | 820 |
| KH-80GF | 113 | 100 | YC4D140-D31 | 1890*750*1140 | 900 |
| KH-90GF | 125 | 113 | YC4D155-D31 | 1890*750*1140 | 930 |
| KH-80GF | 113 | 100 | YC4A140-D30 | 2020*780*1250 | 1000 |
| KH-90GF | 125 | 113 | YC4A155-D30 | 2020*780*1250 | 1030 |
| KH-90GF | 125 | 113 | YC4A165-D30 | 2020*780*1250 | 1030 |
| KH-110GF | 150 | 138 | YC4A190-D30 | 2140*780*1250 | 1100 |
| KH-120GF | 165 | 150 | YC6A205-D30 | 2440*960*1380 | 1420 |
| KH-140GF | 188 | 175 | YC6A230-D30 | 2500*960*1380 | 1460 |
| KH-150GF | 200 | 188 | YC6A245-D30 | 2530*960*1380 | 1500 |
| KH-160GF | 225 | 200 | YC6A275-D30 | 2530*960*1380 | 1500 |
| KH-200GF | 275 | 250 | YC6MK350-D30 | 2900*1130*1580 | 1960 |
| KH-250GF | 350 | 313 | YC6MK420-D30 | 3000*1130*1580 | 2260 |
| KH-280GF | 375 | 350 | YC6MK450-D30 | 3000*1130*1580 | 2260 |
| KH-300GF | 413 | 375 | YC6K500-D31 | 3200*1200*1800 | 3100 |
| KH-300GF | 413 | 375 | YC6K500-D30 | 3200*1200*1800 | 3100 |
| KH-320GF | 438 | 400 | YC6K520-D30 | 3400*1200*1800 | 3200 |
| KH-350GF | 480 | 438 | YC6K600-D30 | 3600*1200*1800 | 3400 |
| KH-400GF | 550 | 500 | YC6K660-D30 | 3700*1350*1950 | 3500 |
| KH-480GF | 660 | 600 | YC6TD780-D31 | 3650*1500*1850 | 4100 |
| KH-500GF | 688 | 625 | YC6TD840-D31 | 3650*1500*1850 | 4200 |
| KH-550GF | 756 | 688 | YC6TD900-D31 | 3650*1580*1900 | 4500 |
| KH-600GF | 825 | 750 | YC6TD1000-D31 | 4650*1650*2200 | 7350 |
| KH-650GF | 895 | 813 | YC6TH1070-D31 | 4700*1500*2050 | 7500 |
| KH-720GF | 990 | 900 | YC6TH1220-D31 | 4700*1500*2050 | 7600 |
| KH-800GF | 1100 | 1000 | YC6TH1320-D31 | 4900*1600*2150 | 7750 |
| KH-1000GF | 1375 | 1250 | YC12VTD1500-D30 | 4900*1600*2150 | 7800 |
| KH-1100GF | 1513 | 1375 | YC12VTD1830-D30 | 4900*1600*2150 | 7850 |
| KH-1200GF | 1650 | 1500 | YC12VTD2000-D30 | 5600*2200*2800 | 12800 |
| KH-1400GF | 1925 | 1750 | YC12VC2270-D31 | 5600*2200*2800 | 14200 |
| KH-1500GF | 2063 | 1875 | YC12VC2510-D31 | 6500*2300*2800 | 16000 |
| KH-1600GF | 2200 | 2000 | YC12VC2700-D31 | 8000*2800*3200 | 17800 |
| KH-1800GF | 2475 | 2250 | YC12VC3000-D30 | 8000*2800*3200 | 18000 |
| KH*2000GF | 2750 | 2500 | YC16VC3300-D31 | 8000*3000*3200 | 18400 |
| KH-2200GF | 3025 | 2750 | YC16VC3600-D31 | 8000*3000*3200 | 18600 |
| KH-2400GF | 3300 | 3000 | YC16VC4000-D31 | 8000*3000*3200 | 18780 |
Yuchai T2(60Hz) bilan ishlaydi
| Genset modeli | Rezerv energiyasi | Bosh qudrat | Motor modeli | O'lchamlar (mm) | Vazn(kg) |
| KVA | KVA | ||||
| KH-40GF | 55 | 50 | YC4D65-D20 | 1810*780*1120 | 740 |
| KH-50GF | 69 | 63 | YC4D80Z-D20 | 1900*750*1120 | 780 |
| KH-64GF | 88 | 80 | YC4D100Z-D20 | 1950*770*1230 | 1040 |
| KH-80GF | 110 | 100 | YC6B130Z-D20 | 2150*850*1250 | 1180 |
| KH-94GF | 129 | 117 | YC6B160Z-D20 | 2320*900*1280 | 1250 |
| KH-108GF | 150 | 136 | YC6B210L-D20 | 2430*900*1280 | 1320 |
| KH-125GF | 173 | 157 | YC6B210L-D20 | 2430*900*1280 | 1350 |
| KH-150GF | 206 | 188 | YC6A245L-D20 | 2490*960*1400 | 1500 |
| KH-213GF | 294 | 267 | YC6MK360L-D20 | 2970*1125*1630 | 2060 |
| KH-255GF | 351 | 319 | YC6MK420L-D21 | 2970*1125*1630 | 2240 |
| KH-292GF | 401 | 365 | YC6MJ515L-D22 | 3060*1125*1650 | 2350 |
| KH-334GF | 460 | 418 | YC6MJ515L-D22 | 3450*1240*1868 | 3380 |
| KH-364GF | 501 | 456 | YC6T660L-D21 | 3520*1240*1868 | 3490 |
| KH-400GF | 550 | 500 | YC6T660L-D21 | 3520*1240*1868 | 3620 |
Yuchai T3(60Hz) bilan ishlaydi
| Genset modeli | Rezerv energiyasi | Bosh qudrat | Motor modeli | O'lchamlar (mm) | Vazn(kg) |
| KVA | KVA | ||||
| KH-80GF | 113 | 100 | YC4D140-D33 | 1890*750*1140 | 900 |
| KH-90GF | 125 | 113 | YC4D155-D33 | 1890*750*1140 | 930 |
| KH-80GF | 113 | 100 | YC4D180-D33 | 2020*780*1250 | 1000 |
| KH-120GF | 165 | 150 | YC4A205-D32 | 2440*960*1380 | 1420 |
| KH-150GF | 200 | 188 | YC6A245-D32 | 2530*960*1380 | 1500 |
| KH-160GF | 225 | 200 | YC6A285-D32 | 2530*960*1380 | 1500 |
| KH-200GF | 275 | 250 | YC6MK360-D30 | 2900*1130*1580 | 1960 |
| KH-250GF | 350 | 313 | YC6MK420-D31 | 3000*1130*1580 | 2260 |
| KH-280GF | 375 | 350 | YC6MK500-D32 | 3000*1130*1580 | 2260 |
| KH-300GF | 413 | 375 | YC6MK500-D32 | 3200*1200*1800 | 3100 |
| KH-480GF | 660 | 600 | YC6TD780-D32 | 3650*1500*1850 | 4100 |
| KH-500GF | 688 | 625 | YC6TD840-D32 | 3650*1500*1850 | 4200 |
| KH-550GF | 756 | 688 | YC6TD940-D32 | 3650*1580*1900 | 4500 |
| KH-600GF | 825 | 750 | YC6TD1020-D32 | 4650*1650*2200 | 7350 |
| KH-650GF | 895 | 813 | YC6TH1070-D33 | 4700*1500*2050 | 7500 |
| KH-720GF | 990 | 900 | YC6TH1220-D33 | 4700*1500*2050 | 7600 |
| KH-800GF | 1100 | 1000 | YC6TH1350-D33 | 4900*1600*2150 | 7750 |
| KH-1000GF | 1375 | 1250 | YC12VTD1680-D32 | 4900*1600*2150 | 7800 |
| KH-1100GF | 1513 | 1375 | YC12VTD1860-D32 | 4900*1600*2150 | 7850 |
| KH-1200GF | 1650 | 1500 | YC12VTD2070-D32 | 5600*2200*2800 | 12800 |
| KH-1400GF | 1925 | 1750 | YC16VTD2270-D32 | 6500*2300*2800 | 15300 |
| KH-1500GF | 2063 | 1875 | YC16VTD2510-D32 | 6500*2300*2800 | 16000 |
| KH-1600GF | 2200 | 2000 | YC16VTD2700-D32 | 8000*2800*3200 | 17800 |
KAIHUA Xizmat Komandalari sizning barcha muammolaringizga tez javob beradi. Dunyo bo'ylab bizning distributory doimiy KAIHUA mahsulotlari bo'yicha o'qituviga ega. Bu, xizmat agentlarimiz va distributoryning xizmatni to'g'ri amalga oshirishini ta'minlaydi va Baifa standarti bilan, xizmat sifatini va natijani ta'minlaydi.
Oldindan sotish xizmati

-Sotuv oldidan mavjud texnik xizmat
-Mijozlar uchun tushuntiruvli dizayn va tanlovni bajarish
-Mijozlar uchun jihoz xonasi dizaynini va tartibini yordam berish
-Mijozlardan texnik maslahat olish
Xizmat sotishi

Kaihua sizga yetkazib berish sifatini ta'minlash uchun jihoz ish jadvalini taqdim etadi.
Qadoqlash
Kaihua generatorlar eksport qilinishi paytida plyudabrda standard bo'lib paketlanadi (FCL larni nüqtadan olib tashlab)
Техник қўллаб-қувватлаш

Kaihua sifatli, jihohdo komprehsiv va professonal xizmatlarni taqdim etish uchun baland efektda ishlaydigan jamoa egadir.
24/7 reja bo'yicha ish joyida baland samarali va ishonchli ishlaydi.
Sotuvdan keyin

-Jihoz o'rnatish, debag va ishlaydi
-Atrof-muhit sinov testi
-Foydalanuvchilar uchun harakat va xizmatlash turini o‘rganish
-Xato tuzatish va muammolarni hal etish
-OEM qismalarini taklif etish
Xizmat kafolati

-Xizmatdan keyin va muddatli tekshiruvdan so‘ng foydalanuvchilar tarixini belgilash
-Foydalanuvchining operatori uchun markaziy ta’limni tashkil etish
-Maxsus shartlarda bizning xodimlar mijozning talabiga ko‘ra vazifada bo‘lishi mumkin
Kafolat
Barcha Kaihua mahsulotlari foydalanuvchilari aksizlik bilan ega bo‘ladi. Bizning har bir mahsuloti kamida 1000 soat ishlaydi/ 12 oy garantiya xizmati bilan qoplangan.
Xizmat bo‘limimiz har bir texnik muammosiga to‘llantirilmagan va tez qo‘llab-quvvatlashni taminlaydi, va normal generator ishlashini davom ettirish uchun yechim beradi. Iltimos, mahalliy distributorgingizni chaqiring yoki savdo menejerингиз билан bog'laning.
Ehtiyot qismlar
Asal ishlab chiqaruvchi yetkazib berilgan asli qism xizmati va sotuvchi
24 soat ichida tez javob va jahon bo‘ylab yetkazib berish