Genset Model |
Standby Power |
Prime power |
Engine Model |
Dimention |
Weight |
||
KVA |
KW |
KVA |
KW |
mm |
KG |
||
KH-15GF |
22 |
18 |
18.75 |
15 |
4B3.9-G2 |
1160*750*1200 |
800 |
KH-20GF |
28 |
22 |
25 |
20 |
4B3.9-G2 |
1160*750*1200 |
800 |
KH-24GF |
33 |
26 |
30 |
24 |
4B3.9-G2 |
1160*750*1200 |
800 |
KH-32GF |
44 |
35 |
40 |
32 |
4BT3.9-G2 |
1160*750*1200 |
810 |
KH-48GF |
69 |
55 |
60 |
48 |
4BTA3.9-G2 |
1860*750*1200 |
850 |
KH-64GF |
83 |
66 |
80 |
64 |
6BT5.9-G2 |
2160*800*1300 |
1040 |
KH-80GF |
110 |
88 |
100 |
80 |
6BT5.9-G2 |
2160*800*1300 |
1056 |
KH-92GF |
132 |
106 |
115 |
92 |
6BTA5.9-G2 |
2160*800*1300 |
1096 |
KH-104GF |
149 |
119 |
130 |
104 |
6BTAA5.9-G2 |
2300*850*1300 |
1400 |
KH-150GF |
198 |
158 |
187.5 |
150 |
6CTA8.3-G2 |
2400*860*1380 |
1440 |
KH-180GF |
220 |
176 |
225 |
180 |
6CTAA8.3-G2 |
2500*960*1450 |
1700 |
KH-200GF |
275 |
220 |
250 |
200 |
6LTAA8.9-G2 |
2640*970*1450 |
2000 |
Model |
Standby Power |
Prime Power |
Engine Model |
Dimension |
Weight |
||
KVA |
KW |
KVA |
KW |
KG |
|||
KH-50GF |
68.8 |
55 |
62.5 |
50 |
DB58 |
1800 x730x1250 |
810 |
KH-64GF |
88.0 |
70.4 |
80 |
64 |
D1126 |
2300x790x1500 |
1500 |
KH-75GF |
103.1 |
82.5 |
93.7 |
75 |
D1146T |
2300x790x1500 |
1500 |
KH-90GF |
123.8 |
99 |
112.5 |
90 |
D1146T |
2300x790x1500 |
1500 |
KH-100GF |
137.5 |
110 |
125 |
100 |
P086T1-1 |
2650x950x1400 |
1800 |
KH-120GF |
165.0 |
132 |
150 |
120 |
P086T1-1 |
2650x950x1400 |
1800 |
KH-150GF |
206.3 |
165 |
187.5 |
150 |
P086T1 |
2650x950x1400 |
1800 |
KH-200GF |
275.0 |
220 |
250 |
200 |
P126T1 |
2960x1030x1500 |
2315 |
MODEL |
Standby Power |
Prime Power |
Engine Model |
Dimension |
Weight (KG) |
||
KVA |
KW |
KVA |
KW |
||||
KH-40GF |
55 |
44 |
50 |
40 |
BF4M2012 |
2000x750x1300 |
1050 |
KH-50GF |
69 |
55 |
63 |
50 |
BF4M2012C |
2000x750x1300 |
1100 |
KH-80GF |
110 |
88 |
100 |
80 |
BF4M1013EC |
2150x750x1550 |
1200 |
KH-100GF |
138 |
110 |
125 |
100 |
BF4M1013FC |
2150x750x1550 |
1380 |
KH-120GF |
165 |
132 |
150 |
120 |
BF6M1013EC |
2473x900x1546 |
1330 |
KH-150GF |
206 |
165 |
188 |
150 |
BF6M1013FC G2 |
2600x1010x1700 |
1820 |
KH-160GF |
220 |
176 |
200 |
160 |
BF6M1013FC G3 |
2600x1010x1700 |
1820 |
KH-180GF |
248 |
198 |
225 |
180 |
BF6M1015-LA GA |
2600x1140x1800 |
1880 |
KH-200GF |
275 |
220 |
250 |
200 |
BF6M1015C-LA G1A |
3060x1315x2035 |
2300 |
KH-220GF |
303 |
242 |
275 |
220 |
BF6M1015C-LA G2A |
3060x1315x2035 |
2300 |
KH-250GF |
344 |
275 |
313 |
250 |
BF6M1015C-LA G3A |
3060x1315x2035 |
2300 |
KH-280GF |
385 |
308 |
350 |
280 |
BF6M1015C-LA G4 |
3060x1315x2035 |
2300 |
KH-300GF |
413 |
330 |
375 |
300 |
BF6M1015CP-LA G |
3060x1315x2035 |
2300 |
KH-350GF |
481 |
385 |
438 |
350 |
BF8M1015C-LA G1A |
3208x1515x1975 |
2870 |
KH-360GF |
495 |
396 |
450 |
360 |
BF8M1015C-LA G2 |
3208x1815x1978 |
3190 |
KH-380GF |
523 |
418 |
475 |
380 |
BF8M1015CP-LA G1A |
3208x1815x1978 |
3190 |
KH-400GF |
550 |
440 |
500 |
400 |
BF8M1015CP-LA G2 |
3208x1815x1978 |
3190 |
KH-410GF |
564 |
451 |
513 |
410 |
BF8M1015CP-LA G3 |
3208x1815x1978 |
3190 |
KH-430GF |
591 |
473 |
538 |
430 |
BF8M1015CP-LA G4 |
3208x1815x1978 |
3190 |
KH-450GF |
619 |
495 |
563 |
450 |
BF8M1015CP-LA G5 |
3208x1815x1978 |
3190 |
KH-550GF |
756 |
605 |
688 |
550 |
HC12V132ZL-LAG1A |
4000x1850x2015 |
4120 |
KH-600GF |
825 |
660 |
750 |
600 |
HC12V132ZL-LAG2A |
4000x1850x2015 |
4120 |
Genset Model |
Standby Power |
Prime Power |
Engine Model |
Dimension |
Weight (KG) |
||
KVA |
KW |
KVA |
KW |
||||
KH-8GF |
11 |
8.8 |
10 |
8 |
403A-11G1 |
1100x450x940 |
290 |
KH-10GF |
13.75 |
11 |
12.5 |
10 |
403A-15G1 |
1200x500x1000 |
380 |
KH-16GF |
22 |
17.6 |
20 |
16 |
404A-22G1 |
1350x530x1000 |
456 |
KH-20GF |
27.5 |
22 |
25 |
20 |
1103A-33G |
1740x730x1565 |
762 |
KH-24GF |
33 |
26.4 |
30 |
24 |
1103A-33G |
1740x730x1565 |
762 |
KH-36GF |
49.5 |
39.6 |
45 |
36 |
1103A-33TG1 |
2030x730x1565 |
870 |
KH-50GF |
68.75 |
55 |
62.5 |
50 |
1104A-44TG1 |
2135x730x1595 |
978 |
KH-64GF |
88 |
70.4 |
80 |
64 |
1104A-44TG2 |
2135x730x1595 |
1018 |
KH-80GF |
110 |
88 |
100 |
80 |
1104C-44TAG2 |
2235x730x1595 |
1090 |
KH-100GF |
137.5 |
110 |
125 |
100 |
1106A-70TG1 |
2565x730x1575 |
1376 |
KH-120GF |
165 |
132 |
150 |
120 |
1106A-70TAG2 |
2565x730x1575 |
1416 |
KH-140GF |
192.5 |
154 |
175 |
140 |
1106A-70TAG3 |
2645x730x1630 |
1644 |
KH-160GF |
220 |
176 |
200 |
160 |
1106A-70TAG4 |
2645x730x1630 |
1644 |
KH-180GF |
247.5 |
198 |
225 |
180 |
1506A-E88TAG2 |
3035x900x1525 |
1695 |
KH-200GF |
275 |
220 |
250 |
200 |
1506A-E88TAG3 |
3035x900x1525 |
2035 |
Genset Model |
Standby Power |
Prime power |
Engine model |
Dimension |
Weight (KG) |
||
KVA |
KW |
KVA |
KW |
||||
KH-68GF |
93.5 |
74.8 |
85 |
68 |
TAD530GE |
2080x720x1450 |
1090 |
KH-75GF |
103.1 |
82.5 |
93.75 |
75 |
TAD531GE |
2080x720x1450 |
1150 |
KH-80GF |
110.0 |
88 |
100 |
80 |
TAD531GE |
2080x720x1450 |
1150 |
KH-90GF |
123.8 |
99 |
112.5 |
90 |
TAD532GE |
2280x900x1450 |
1250 |
KH-100GF |
137.5 |
110 |
125 |
100 |
TAD532GE |
2280x900x1450 |
1250 |
KH-120GF |
165.0 |
132 |
150 |
120 |
TAD731GE |
2400x870x1450 |
1560 |
KH-150GF |
206.8 |
165 |
188 |
150 |
TAD732GE |
2600x1050x1500 |
1600 |
KH-180GF |
247.5 |
198 |
225 |
180 |
TAD733GE |
2600x1050x1670 |
1800 |
KH-200GF |
275.0 |
220 |
250 |
200 |
TAD734GE |
2600x1120x1770 |
2700 |